Basic Info
  • Model NO.: PTC-8125D1(ANSI 1S)
  • Maxcapacity: 50-288V
  • Load Way: Electronic Load
  • Display: Digital
  • Weight: 100-500Kg
  • Oil Cylinder Position: Under
  • Reference Standard Energy Meter: Hc3101A Accuracy Class: 0.05 /0.1
  • 2.9numbers of Calibrated Energy Meter: 24 (12/24/48/60 on Requested
  • Specification: 0.05 / 0.1
  • HS Code: 9030849000
  • Type: Universal Testing Machine
  • Accuracy Grade: 0.05 / 0.1
  • Loading Method: Static Load
  • Control: Computer Control and Manual Control
  • Power Source: 50-288V
  • The Test Bench Accuracy Class: 0.05 / 0.1
  • Output Frequency Range: 45Hz~65Hz; Resolution: 0.01Hz
  • Trademark: Hanpu
  • Origin: Zhejiang Jiaxing
Product Description
1. Functions
1.1 With specialized ANSI meter, the worker needn't to insert and extract,and the bench is suitable for FORM-2S meter. 
1.2 For FORM-2S meter, it is 2P3W and includes two sources, CT and reference meter. For FORM-2S meter, there are two types: open-link and close link. FORM-2S can be used universally with FORM-1S.
1.3 The energy meter hanging rack is made by Aluminum compound. The test bench can be installed scanning head. It is also can be accepted the signal for digital LED energy meter.
1.4 The bench uses PC to operate, The bench can automatically do starting test, no load test(creep test), error test(accuracy test), deviation test, 24h variation test and so on.Test items and condition are flexible, and we can define the test scheme or use the standard test scheme. The test result can store in the data library .The bench can connect to the guest's net and upload the data.
2Features
2.1 The multifunction reference meter and power source assort with the equipment can be used independently, and it is convenient to repair.
2.2 The bench is using the PWM, technology to amplify voltage/current
output, the high efficiency at >85%, and lower the heat. The PWM can
check the malfunction checking, preset, alarm, and protection.
2.3 The MTS software platform is very powerful, the main operations are in one interface, the operation is extremely easy; and with the SQL SERVER large databases, it is security and stability, the amount of data is almost unlimited.
2.4 The bench is using the error processor system to calculate the error of each energy meter by the sub-error system which can be connected by the internal RS485.
2.5 The test bench has the auto-search black marker function which can
precisely locate the black marker 
2.6 Automatic range switching. The bench can choose to operate by
keyboard or PC which is very convenient.
2.7 Electronic protection in case of over load, short circuit and output
current open status.
2.8 The whole device configuration is a reasonable design and nice outfit.
3Specification
3.1 Reference standard energy meter: HC3100H Accuracy class: 0.02
3.2 Output Voltage: 120V              
 Adjustment range: 0 ~ 120%;  Fine adjustment: better than 0.01%
3.3 Output current: 200A max
  Adjustment range: 0 ~ 120%;  Fine adjustment: better than 0.01%
3.4 Phase range :0-359 .9 °;    Fine adjustment: 0.01 °
3.5 Frequency :45-65Hz; Fine adjustment: 0.01Hz
3.6Output waveform distortion coefficient: voltage, current ≤ 0.5%
3.7 Output voltage, current, power stability ≤ 0.05% (180s)
3.8 Load: resistive, inductive and capacitive
3.9 Starting current output: 5mA (min), accuracy: ≤ 5%; starting power: accuracy: ≤ 5%
3.10 Meter number:12
3.11Environmental condition: operating environment temperature: 20ºC±5ºCambient environment humidity: 40% -60% RH
3.12 Power supply: single phase AC220V ± 15%, frequency: 50 ± 5% Hz
3.13 Weight:
3.14 Dimensions:
Type of benchmeterNumbersize (L × W × H) Unit: mmMaximum power consumption
 
Fission
1011800 × 700 × 1850 VA
2021800 × 700 × 1850 VA
4822600 × 700 × 1920 VA
 
Internal Connection figure
 