Zhejiang, China
Number of Employees:
344
Registered Capital:
10.2 Million USD
Plant Area:
6196 square meters
Management System Certification:
ISO9001:2008, ISO14001:2004, OHSAS18001:2007
OEM/ODM Service
Sample Available

Meter Test Bench, Energy Meter Calibration Device, Three Phase Meter Test Bench manufacturer / supplier in China, offering Three Phase Close-Link Energy Meter Test Bench, Three Phase Close-Link Kwh/Electric/Energy Meter Test Bench with Isolated CT (PTC-8320E), Three Phase Close-Link Energy Meter Test Bench with Isolated CT and so on.

Gold Member Since 2015
Audited Supplier

Three Phase Close-Link Energy Meter Test Bench

Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 3000
Payment Terms: L/C, T/T
Type: Universal Testing Machine
Maxcapacity: 3X57.7V/100V/220V/380V (Phase Voltage)
Accuracy Grade: 0.05/0.1
Load Way: Electronic Load
Loading Method: Static Load
Display: Digital

You Might Also Like

Loading...

Basic Info

Model NO.
PTC-8320E T
Control
Computer Control and Manual Control
Weight
100-500Kg
Power Source
AC 3X220V +-15%
Oil Cylinder Position
Under
The Test Bench Accuracy Class
0.05/0.1 Class
Reference Standard Energy Meter
Hc3101A Accuracy Class: 0.05 /0.1
Output Frequency Range
45Hz~65Hz; Resolution: 0.01Hz
2.9numbers of Calibrated Energy Meter
6
Trademark
Hanpu
Transport Package
Standard Wooden Case
Specification
Accuracy class: 0.05 / 0.1
Origin
Zhejiang Jiaxing
HS Code
9030849000
1.Features
1.1 The bench accords with the standard of "IEC 60736:1982 testing
equipment for electrical energy meters", "IEC 62053"
1.2 Close-link and ordinary calibration both can be used, ordinary
calibration can be used to test single/three phase active and reactive
energy meter(up to 0.5 class),close-link calibration can be used to test
single/three phase active and reactive energy meter(up to 1 class).
1.3 The bench can test the converted quantity which is caused by negative
phase, voltage unbalance, harmonic wave and so on.
1.4 The bench can auto-calibrate starting, no load, basic error and
calibration tolerance and 24h deflection.
1.5 Close-link calibration is using insulate current transformer and
suitable for close-link energy meter.
1.6 The bench is using the error processor system to calculate the error of
each energy meter by the sub-error system which can be connected by the
internal RS485.
1.7 The same specification but different constant energy meter can be
tested at one time.
1.8 For the installed pick-up equipment, can offer 3 ranges adjustment. It
is also can be accepted the signal for both round-style energy meter and
digital LED energy meter.
1.9 The bench can choose to operate by keyboard or PC which is
convenient. The working status of bench can be seen very clear and easy
operation.
1.10 The bench is using the testing software complied with
WINDOWS98/2000/XP which can auto-testing different energy meters. 
1.11 The software can realize the data from energy meter for statistics,
search and management. It also can connect with on-line management for
up load the data.
1.12 The energy meter hanging rack is made by Aluminum compound.
The whole device configuration is a reasonable design and nice outfit.


2. Specification
2.1 accuracy class: 
0.1 class (close-link calibration, the range of current: 0.1A-100A) (200A optional)
0.05/0.1 class (open-link calibration)
2.2 standard power testing equipment
   HC 3100H   Accuracy class: 0.02 class
2.3  Isolated current transformer equipment:  
PTC-9503B insulate current inductance
Accuracy class:0.1(COSφ=0.5C-1-0.5L,0.1-100A) (200A optional)
Output power:30VA(MAX,100A)
2.4 Voltage amplifier:
Output voltage range: 30-400V (phase-neutral)
                   50-600V (phase-phase)
  Output maximum power: 800VA (every meter)
Resolution: 0.01%;
Stability: better than 0.05%/180s (time base 5s);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: more than 85%;
Ambient temperature:10ºC~50ºC
   Electronic overload and short-circuit protection.
2.5 Current amplifier:
Output current: range: 1mA~100A (200A optional)
Output maximum power: 1500VA
Resolution: 0.01%;
Stability: better than 0.05%/180s (time base 5s);
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: greater than 85%;
Ambient temperature:10ºC~50ºC
   Electronic overload protection and security for open current circuit.
2.6 Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
2.7 Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
2.8 Harmonic wave output:
2-21 sub-harmonic wave contents=40%
         3,5,7 sub-harmonic wave couping, total content=40%
         Phase angel control (odd sub-harmonic wave)
         Wave group control (sub-harmonic wave)
2.9 Output stability of power: <0.05% (180s)
2.10 Numbers of calibrated energy meter: 8-20
2.11Input power: 3x220/380V(Y) 15%, 50/60Hz; Max. power consumption: 6000VA 
2.12 Weight:
2.13Dimension:
Type of benchMeters Number Number of rowSize 
Fission12112000×750×1920mm
16112400×750×1920mm
20112800×750×1920mm
 
3. Other details
Three Phase Close-Link Energy Meter Test Bench

 

Send your message to this supplier

*From:
*To:
avatar Miss Cathy Xiao
*Message:

Enter between 20 to 4,000 characters.